二、设置步骤
1、将两台防火墙的第四个端口连接在一起,我们设置将原有防火墙设置为主防火墙,新增加的防火墙为备份的防火墙,备份的防火墙只连接第四个端口,其他的端口将在防火墙配置完毕后才连接上
2、使用终端线缆连接到防火墙的Console口,超级终端参数设置为9600-8-无-1-无。
三、命令行配置方式
蓝色字体为在超级终端上输入的命令
3.1、主防火墙配置(线上环境正在使用的防火墙)
unset interface e4 ip 将端口4的IP地址删除, set interface e4 zone ha 将端口4和HA区域绑定一起
查看NSRP状态
get nsrp 查看NSRP配置信息 nsrp version: 2.0 cluster info: cluster id not set: nsrp is inactive 默认的情况下NSRP没有激活 VSD group info: init hold time: 5 heartbeat lost threshold: 3 heartbeat interval: 1000(ms) group priority preempt holddown inelig master PB other members total number of vsd groups: 0 Total iteration=3808,time=2721060,max=880,min=286,average=714 RTO mirror info: run time object sync: disabled ping session sync: enabled coldstart sync done nsrp link info: no nsrp link has been defined yet NSRP encryption: disabled --- more --- NSRP authentication: disabled NSRP monitor interface: none number of gratuitous arps: 4 (default) track ip: disabled
配置NSRP ns204-set nsrp cluster id 1 设置cluster组号 ns204(M)-set nsrp vsd id 0 设置VSD的组号,这条命令可以不用输入,因为Netscreen防火墙的默认的虚拟安全数据库(VSD)的值是0。 ns204(M)-set nsrp vsd-group id 0 priority 50 设置NSRP主设备的优先权值,priority值越小,优先权越高。 ns204(M)-set nsrp rto syn 设置配置同步 ns204(M)-set nsrp monitor interface ethernet3 设置防火墙监控的端口,假设端口3出现故障或所连接的交换机出现故障,防火墙的工作状态将切换到备份防火墙上。 ns204(M)-set nsrp monitor interface ethernet1 设置防火墙监控的端口,假设端口1出现故障或所连接的交换机出现故障,防火墙的工作状态将切换到备份防火墙上。
注:如没有监控端口2,端口2出现故障或连接网络出现故障,将不会激活防火墙工作状态切换
ns204(M)-get nsrp nsrp version: 2.0 cluster info: cluster id: 1, no name local unit id: 5609296 active units discovered: index: 0, unit id: 5609296, total number of units: 1 VSD group info: init hold time: 5 heartbeat lost threshold: 3 heartbeat interval: 1000(ms) group priority preempt holddown inelig master PB other members 0 50 no 3 no myself none (备份防火墙还没有配置,因此主设备上没有监测到Backup防火墙的状态) total number of vsd groups: 2 Total iteration=4682,time=4184162,max=18848,min=286,average=893 RTO mirror info: run time object sync: disabled ping session sync: enabled nsrp link info: no nsrp link has been defined yet NSRP encryption: disabled NSRP authentication: disabled NSRP monitor interface: ethernet1 ethernet3 number of gratuitous arps: 4 (default) track ip: disabled
ns204(M)->
设置NSRP心跳信息 ns204(M)-set nsrp vsd-group hb-interval 200 设置心跳信息每隔200秒将发出问候信息 ns204(M)-set nsrp vsd-group hb-threshold 3 设置心跳信息总共发出3次问候信息 ns204(M)-save
3.2、备份防火墙的配置:(新增加的防火墙)
ns204- unset all 将新增防火墙的原有配置清除,恢复出厂状态 Erase all system config, are you sure y/[n] ? y ns204- reset Configuration modified, save? [y]/n n System reset, are you sure? y/[n] y In reset ... ................................................................. ................................................................. ................................................................. ns204- set interface e4 zone ha 将端口4和HA区域绑定一起
配置NSRP ns204- set nsrp cluster id 1 设置cluster组号 ns204(B)- set nsrp vsd id 0 设置VSD的组号,这条命令可以不用输入,因为Netscreen防火墙的默认的虚拟安全数据库(VSD)的值是0。 ns204(B)- set nsrp vsd-group id 0 priority 100 设置NSRP主设备的优先权值,priority值越小,优先权越高。 ns204(B)- set nsrp rto syn 设置配置同步 ns204(B)- set nsrp monitor interface ethernet3 设置防火墙监控的端口,假设端口3出现故障或所连接的交换机出现故障,防火墙的工作状态将切换到备份防火墙上。 ns204(B)- set nsrp monitor interface ethernet1 设置防火墙监控的端口,假设端口1出现故障或所连接的交换机出现故障,防火墙的工作状态将切换到备份防火墙上。
注:如没有监控端口2,端口2出现故障或连接网络出现故障,将不会激活防火墙工作状态切换
ns204(B)- get nsrp nsrp version: 2.0 cluster info: cluster id: 1, no name local unit id: 5609745 active units discovered: index: 0, unit id: 5609745, total number of units: 1 VSD group info: init hold time: 5 heartbeat lost threshold: 3 heartbeat interval: 1000(ms) group priority preempt holddown inelig master PB other members 0 50 no 3 no 5609296(主设备) myself total number of vsd groups: 2 Total iteration=4682,time=4184162,max=18848,min=286,average=893 RTO mirror info: run time object sync: disabled ping session sync: enabled nsrp link info: no nsrp link has been defined yet NSRP encryption: disabled NSRP authentication: disabled NSRP monitor interface: ethernet1 ethernet3 number of gratuitous arps: 4 (default) track ip: disabled
设置NSRP心跳信息 ns204(B)- ns204(B)- set nsrp vsd-group hb-interval 200 设置心跳信息每隔200秒将发出问候信息 ns204(B)- set nsrp vsd-group hb-threshold 3 设置心跳信息总共发出3次问候信息 ns204(B)- save
3.3、同步配置
该步骤将主防火墙的配置和备份防火墙的配置进行同步,(强调一点,设置前请先将主防火墙的配置备份一次。)。
使用超级终端登陆备份防火墙的console端口。
使用一下命令:
ns204(B)- exec nsrp sync rto all from peer (将从主设备上向备份主机同步会话状态信息) ns204(B)- exec nsrp sync file from peer (将从主设备上向备份主机同步配置信息) ns204(B)- exec nsrp sync global-config check-sum (将两台设备的配置进行校检,如有不同,备份的设备将会在重启后把主设备上的配置导入备份主机中) ns204(B)- exec nsrp sync global-config save (如有不同,备份的设备将会在重启后把主设备上的配置导入备份主机中)
以下信息只有在超级终端上才有显示:
ns204(B)- configuration in sync (local checksum 789579268 == remote checksum 789579268) sync all files from peer done Received all run-time-object from peer. configuration in sync (local checksum 789579268 == remote checksum 789579268) load peer system config to save Save global configuration successfully. Save local configuration successfully. done. Please reset your box to let cluster configuration take effect! 重启备份防火墙,在重启的过程中,备份的防火墙将会从主设备上同步配置 ns204(B)- reset
Netscreen 防火墙的冗余配置结束。
四、图形界面下的配置步骤
4.1、登陆防火墙的图形管理界面
选择network>Interface> Ethernet4 > edit
NSRP设置
选择Network > Redundancy >Settings
在Cluster ID中输入1,选择NSRP RTO Mirror Synchronization
选择Monitor Port > Edit > 选择Ethernet 1和ethernet3
VSD设置
选择Network > Redundancy > VSD Group > New
在Group ID中输入0,在Prority 中输入优先权值100
同样的步骤配置备份的防火墙
4.2、同步配置
该步骤将主防火墙的配置和备份防火墙的配置进行同步,(强调一点,设置前请先将主防火墙的配置备份一次。)。
使用超级终端登陆备份防火墙的console端口。
使用以下命令:
ns204(B)-> exec nsrp sync rto all from peer (将从主设备上向备份主机同步会话状态信息)
ns204(B)-> exec nsrp sync file from peer (将从主设备上向备份主机同步配置信息)
ns204(B)-> exec nsrp sync global-config check-sum (将两台设备的配置进行校检,如有不同,备份的设备将会在重启后把主设备上的配置导入备份主机中)
ns204(B)-> exec nsrp sync global-config save (如有不同,备份的设备将会在重启后把主设备上的配置导入备份主机中)
以下信息只有在超级终端上才有显示:
ns204(B)-> configuration in sync (local checksum 789579268 == remote checksum 789579268)
sync all files from peer done
Received all run-time-object from peer.
configuration in sync (local checksum 789579268 == remote checksum 789579268)
load peer system config to save
Save global configuration successfully.
Save local configuration successfully.
done.
Please reset your box to let cluster configuration take effect!
重启备份防火墙,在重启的过程中,备份的防火墙将会从主设备上同步配置
ns204(B)-> reset